The Woson Tanda B Class Autoclave, with a 23 Litres capacity, provides a sterilization solution for medical and dental environments. This autoclave is engineered to meet European B Standard requirements, ensuring comprehensive sterilization for a wide array of dental instruments and materials.

Designed to sterilize any autoclavable material, including solid, field, rubber, articulated, porous, cotton, and fabric items, the Woson Tanda B Class Autoclave ensures steam penetration even into complex instruments like hollow-body items and wrapped packs. The chamber is constructed from 304 AISI stainless steel, facilitating internal cleaning and maintenance.

Key Features : 

Versatile sterilization for a broad range of dental instruments and autoclavable materials, including hollow and porous items.
Ensures thorough sterilization with a 3-times pre-vacuum and vacuum drying, achieving effective steam penetration.
Chamber constructed from 304 AISI stainless steel for durability and ease of cleaning.
Complies with European B Standard, including directives 93/42/EEC and 97/23/EC, and standards EN 13060, EN 61010-1, EN 61010-2-040, and EN 61326-1.
Operates with temperature cycles at 121°C and 134°C for effective sterilization.

Material304 AISI stainless steel
Primary Use / IndicationSterilization of dental instruments and autoclavable materials (solid, field, rubber, articulated, porous, cotton, fabric)

Placement & Setup

  • Place the autoclave on a flat, stable, heat-resistant surface with adequate ventilation.
  • Ensure power supply is appropriate (e.g., 220 V ±10%, 50/60 Hz) and the unit is properly grounded.
  • Fill the clean water tank using distilled water only, to avoid scaling and damage.
  • Check that all external connections (power, drainage, water fill) are secure.
  • Preparing Instruments
  • Clean and rinse instruments thoroughly; dry them before placing in the autoclave.
  • Arrange items evenly in the chamber trays or cassettes; do not overload—leave space for steam circulation.
  • For hollow instruments, ensure proper configuration so steam can penetrate.
  • Loading the Chamber
  • Open the door and insert the tray(s) into the chamber.
  • Check the door gasket is clean, intact and properly seated.
  • Close the door securely until locked or latched and ready for operation.
  • Selecting the Sterilization Cycle
  • Power on the unit via the control panel.
  • Select the appropriate B-Class sterilization cycle (e.g., for wrapped/unwrapped, porous/hollow loads) as per load type.
  • Typical temperatures: 121 °C or 134 °C (depending on program).
  • Vacuum phases (pre-vacuum and/or post-vacuum) and drying phases may be part of the cycle (based on model’s B-Class specification).
  • Running the Cycle
  • Press Start to begin the cycle.
  • The unit will automatically go through phases: vacuum, sterilization, exhausting, drying (if applicable).
  • Monitor status via display panel; if error codes appear, refer to troubleshooting section in the manual.
  • Completion & Unloading
  • Wait until the cycle ends, pressure returns to atmospheric, and display indicates safe to open.
  • Carefully open the door slightly to allow steam to escape slowly, then fully open.
  • Using sterilization gloves or tongs, remove load and place on a clean, dry surface. Allow instruments to cool before handling or storing.
  • Post-Use Maintenance
  • Drain any residual water from the chamber and associated tanks.
  • Wipe the chamber interior and trays with a clean, lint-free cloth.
  • Inspect and clean door gasket, filter screens, and drainage ports.
  • Refill the clean water reservoir with fresh distilled water for next use.
  • Periodically run any recommended cleaning or maintenance cycles (e.g., generator cleaning if the model includes one).

Safety Precautions

Do not open the door while pressure remains above ambient; risk of steam burns.

Only use distilled water — avoiding tap or hard water to prevent scaling and damage.

Ensure the unit is connected to a properly grounded power outlet and meets specification.

Do not overload the chamber or block steam circulation; proper air removal is critical in B-Class sterilization.

Follow any device-specific alarm/error codes to ensure safe and correct operation.