The Medtech Medclave Class B Autoclave 23L is an essential sterilizer for modern dental practices, providing safe, effective, and fully compliant sterilization. This compact desktop model is designed for comprehensive sterilization of solid, hollow, porous, and Type A instruments, both packaged and unpackaged, making it suitable for various clinical environments. Constructed with Stainless Steel 304, the autoclave chamber ensures durability and facilitates internal cleaning and maintenance. It meets the EN13060 Class B standard, ensuring adherence to European regulations for sterilizing all types of loads. The unit includes a water distiller, enhancing operational convenience.

Key Features : 

Comprehensive sterilization for solid, hollow, porous, and Type A instruments, whether packaged or unpackaged
Constructed with Stainless Steel 304 for durability and ease of maintenance
EN13060 Class B certified, meeting European standards for sterilization
23-Liter capacity for routine dental instrument sterilization
High-illumination LED interactive display for intuitive program selection and guidance
Integrated thermal paper printer for real-time data recording and audit readiness
Anti-microbial air filtration ensures sterile airflow during drying and pressure equalization phases

MaterialStainless Steel 304
Primary Use / IndicationSterilization of solid, hollow, porous, and Type A instruments


Placement and Setup: 

  • Place the autoclave on a flat, stable surface with sufficient ventilation space around it.
  • Ensure that both the water tank and wastewater tank are properly connected.
  • Fill the clean water tank with distilled water (recommended for optimal performance).
  • Plug the unit into a compatible 220V, 50/60Hz power source.

 Preparation of Instruments: 

  • Clean and dry all instruments thoroughly before sterilization.
  • Arrange instruments evenly on the trays or inside sterilization pouches.
  • Do not overload the chamber—ensure steam can circulate freely.

 Loading the Chamber: 

  • Open the autoclave door and place the trays or cassettes inside.
  • Check that the door gasket is clean and properly seated.
  • Close the door securely until it locks.

 Selecting the Sterilization Cycle: 

  • Power on the unit using the touch screen control panel.
  • Choose the appropriate Class B sterilization cycle based on the instrument type and packaging (e.g., wrapped, unwrapped, hollow).
  • The default operating temperature is 121°C or 134°C, depending on the selected cycle. 

Operation: 

  • Once the program is selected, press Start to begin the cycle.
  • The system will automatically perform vacuum, sterilization, and drying phases.
  • Monitor the progress on the display panel. 

Cycle Completion: 

  • Wait for the pressure to return to zero and for the display to indicate that the cycle is complete.
  • The door will unlock automatically once it is safe to open.
  • Open the door slightly to allow steam to dissipate before removing items. 

Unloading: 

  • Use sterilization gloves to remove trays carefully.
  • Allow instruments to cool before handling or storing. 

Post-Use Maintenance: 

  • Empty the wastewater tank after each cycle.
  • Refill the clean water tank as needed using distilled water.
  • Wipe the chamber dry and ensure the gasket is clean.
  • Run a cleaning cycle weekly using the built-in water distiller to maintain water quality and system efficiency. 

Safety Tips: 

  • Never open the door during the sterilization cycle.
  • Avoid using tap water or chemical solutions inside the tank.
  • Regularly check filters, gaskets, and valves for proper functioning. 