BPL Defibrillators Biphasic Monitoring Screens - Relife 900/AED/R

In stock
SKU
MBBPLM0014
Add To Cart View Price
  • Allows the clear and precise display of multiple waveforms and defibrillation parameters
  • Continuous voice prompts and on screen messages to aid in revival and resuscitation process
  • The current controlled bi-phasic waveforms lowers the electrical threshold for successful defibrillation, besides adjusting for impedance
  • Metronome signal for synchronizing chest compression during CPR
  • 100 charge / discharge of 300J with fully charged new battery
  • Synchronized Cardioversion function is available for providing defibrillation on sync with ECG waveform
  • 2-300 J of energy level can be selected for defibrillation by the user
  • Memorises always the last 24 Critical Event ECG information which can be viewed or recorded+N3
  • Remote energy selection, charging and discharging through paddles facilitate convenient usage
  • Patient-Paddle quality of contact is provided on screen Optional Enhancements:
  • Accurate monitoring of breath rate along with CO2. It comes with Mainstream or Sidestream Option.
  • Accurate SpO2 measurements powered by MasimoSET
  • In Automated External Defibrillator (AED) mode, the shock sequence can be selected based on the requirement
  • Accurate NIBP measurements powered by SunTech
BPL Defibrillators Biphasic Monitoring Screens - Relife 900/AED/R
BPL Defibrillators Biphasic Monitoring Screens - Relife 900/AED/R
Specifications:
Model No Relife 900/AED/R
Manual Defibrillator
Defibrillator Waveform Current Controlled, Biphasic
Energy Selection Option 2-300J in steps of 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 250, 300 Joules
Energy Selection Control Selected using keys located on the front panel or on the sternum paddle.
Paddle Assembly Detachable type external paddle assembly with coiled retractable high voltage cable Adult & paediatric paddles integrated into same handle
Charge Control Control on the front panel and on the apex paddle.
Synchroniser Energy is delivered within 50 msec of the detected R-wave peak. SYNC message displayed on screen. Sync LED illuminates in Sync mode & blinks during each detected QRS wave Sync marker appears on both screen and recorder strip
Patient Impedance 25–200 ohms:Actual patient impedance during shock is displayed on the screen
Charge Time 300 Joules in less than 7 seconds when connected to AC mains 300 Joules in less than 9 seconds with a fully charged new battery
AED (Optional)
Shock Sequence Low-Low-Low/Low-Low-High/Low- High-High Low - 200J and High - 300J (Programmable)
Analysis Control Automatic on attaching electrodes. Additional control on the front panel to restart rhythm analysis
AED Mode Usage Guidance Though voice prompts and on screen text messages
Shock delivery Through external disposable electrodes suitable for patients with weight >25 Kgs.
Shock delivery Control Control on the front panel with blinking LED
ECG analysis time < 15 seconds
Impedance measurement Verifies electrode contact
Movement and artefact detection Continuous examination of signal quality
VF/VT Sensitivity > 90%
Specificity > 95%
Monitor
Display 7 inch Colour TFT
Sweep speed 25 ± 1 mm/sec
ECG Input modes ECG input through Paddles or ECG Patient cable.
ECG Lead selection 3 Lead or 5 Lead cable
Leads off indication LEADS OFF message displayed on the screen.
User gain settings 8 level setting 2.5, 5, 7.5, 10, 15, 20, 30 & 40 mm/mV
Reset recovery Automatic recovery of waveform within 0.5seconds after overload or defibrillation
Pace pulse recognition Detects and rejects pace maker pulses of amplitude between ±2mV and ±700mV and duration between 100microseconds and 2milli seconds.
Common mode rejection >90 dB at 50Hz
Input impedance >2.5 Mohm
Frequency response 0.5 to 40 Hz
Heart rate display 10 to 300 BPM; Accuracy ±2 BPM or 2% whichever is higher.
QRS tone Audible tone with every detection of QRS. Beep volume can be adjusted by users.
Defibrillator protection Available
ECG trace freeze Available & Freezes the ECG trace on the screen. MARK key can be configured to freeze and remove freeze condition. HR, SpO2, NIBP display and Alarms are active in freeze mode.
Single Channel Thermal Recorder (Optional)
Paper speed 25 ± 1 mm/sec
Paper size and type Thermal paper in rolls. 58 mm width, 15 meters.
Event recording Stores and prints 3 seconds pre critical data and 7 seconds post critical event data up to 24 events. Data is retained even after the unit is turned off.
Recorder mode Configurable to print either real time or 6 seconds delayed ECG.
Memory
Event information Last 24 critical events are stored along with ECG information. Events include MARK key press, Shock delivery and HR Alarm violation.
Trend Last 200 NIBP measurement data and last 200 Alarm violation information.
Power and Battery
AC input 100 – 240Vac, 50/60 Hz & < 240 VA
Battery Sealed Lead Acid 12V, 4.5AH; >100 discharges of 300 Joules (With Fully Charged New Battery)
Safety
Classification Class I with internal power supply as per IEC 60601-1
Degree of protection
ECG - Type CF
SpO2 - Type BF
NIBP - Type BF
Paddle - Type BF
Physical and Environmental
Dimensions 370mm (W) x 300mm (D) x 290mm (H)
Weight Less than 8.5Kg. (including battery, external paddles )
Operating temperature 0 to 40° C
Storage temperature -10 to 60° C (except disposable electrodes)
Relative humidity (operating and storage) 15 to 95% non-condensing
MasimoSET SpO2 (Optional)
SpO2
SpO2 Range 1 – 100%
Resolution 1%
Accuracy (During no motion conditions) 70 – 100% ± 2%, in Adults and Paediatrics 0 – 69%, unspecified
Accuracy (During motion conditions) 70 – 100% ± 3%, in Adults and Paediatrics 0 – 69%, unspecified
Averaging time 2-4 / 4-6 / 8 / 10 / 12 / 14 / 16 Seconds (User selectable)
Pulse Rate
Range 25 – 240 bpm
Resolution 1 bpm
Accuracy (During no motion conditions) ± 3 bpm
Accuracy (During motion conditions) ± 5 bpm
Perfusion Index Resolution 0.01%
Low perfusion performance (>0.02% Pulse Amplitude and % Transmission > 5%) Saturation(%SpO2) ± 2% Pulse Rate ± 3 bpm
Masimo ETCO2 (Optional)
ETCO2 (Mainstream Module)
Measurement Method Infrared Spectrum
Measurement Range 0 - 15%
Resolution 0.1%
Unit % mmHg
Accuracy ± 0.2 Vol % + 2% of reading
Warm up time < 10 seconds
Rise Time ?90ms
awRR measurement range 0 - 150bpm
awRR measurement accuracy ± 1bpm
Total system response time < 1 second
ETCO2 (Sidestream Module)
Measurement range 0 - 15%
Resolution 0.1%
Unit %, mmHg
Accuracy ± 0.2 Vol % + 2% of reading
Warm up time < 10 seconds
Rise Time ? 200ms
awRR measurement range 0 - 150bpm
awRR measurement accuracy ± 1bpm
Sample flow rate 50 ml/min ± 10ml/min
Total system response time < 3 secs
Suntech NIBP (Optional)
Method Oscillometric
Operating Modes Manual, Automatic and Stat Blood Pressure Range
Systolic Adult, 40 – 250 mmHg, Paediatric, 40 – 230 mmHg
Diastolic Adult, 20 – 200 mmHg, Paediatric, 20 – 160 mmHg
MAP (Mean Atrial Pressure) Adult: 26 – 220 mmHg, Paediatric: 26 – 183 mmHg
Cuff Pressure Measurement Range 0 to 300 mmHg
Initial Inflation Pressure Adult, 160 mmHg, Paediatric, 140 mmHg
Pressure Transducer Accuracy ± 3 mmHg or 2% of the reading whichever is greater
Cycle Time in Auto mode 1, 2, 3, 5, 10, 15, 30, 60, 90 Minutes (User selectable)
Cycle Time in Stat mode 5 Minutes
Maximum Inflation Time 75 Seconds
Blood Pressure Accuracy Meets accuracy requirements of ANSI/AAMI SP10:2002(R)2008,
EN1060-4:2004 and ISO 81060-2-2009 standards
More Information
BRAND BPL
Write Your Own Review
You're reviewing:BPL Defibrillators Biphasic Monitoring Screens - Relife 900/AED/R
Your Rating

WhatsApp chat

WhatsApp chat