Brand Orikam

What's in the Box

Orikam Hyperlight Portable X-Ray Machine: 1 × Main Unit 1 × Base Stand 1 × Power Adaptor NanoPix RVG Sensor (Size 1): 1 × Intraoral X-Ray Sensor 1 × USB Flash Drive 1 × Sensor Mounting Bracket 1 × USB Extension Cable 1 × Silicone Protective Cover

The Orikam Hyperlight Portable X-Ray Machine With Nanopix RVG Sensor - Size 1 Combo offers a comprehensive solution for advanced dental diagnostics. This pairing is designed for use in clinics, mobile dental units, and point-of-care diagnostics, enabling high-resolution radiographs for accurate diagnosis and effective treatment planning.

The Orikam Hyperlight Portable X-Ray Machine revolutionizes dental radiography with its compact, portable design, built for mobility, precision, and safety. It delivers high-resolution radiographs with wireless convenience and a user-friendly interface. The Hyperlight Portable X-Ray Unit is FDA-cleared as of September 1, 2023, classified as a Class II extraoral source x-ray system under 21 CFR 872.1800.

Complementing the X-ray unit, the Eighteeth Nanopix Dental RVG Sensor - Size 1 is engineered with aerospace-grade APS CMOS and Direct Deposition CSI technology. This technology ensures exceptional image quality, low radiation, and fast image acquisition, all within an ultra-thin 4.4mm sensor body. The Nanopix sensor is ideal for high-precision periapical imaging, endodontics, implant planning, and routine diagnostics.

Key Features : 

Designed for dental diagnostics, intraoral radiography, and point-of-care imaging
Features aerospace-grade APS CMOS and Direct Deposition CSI technology for the sensor
Orikam Hyperlight Portable X-Ray Unit is FDA-cleared (21 CFR 872.1800, Class II, Product Code EHD)

X-Ray Machine
SpecificationDetails
ModelHyperLight
Weight1.8 kg
Focal Spot0.4 mm
Tube Current2.5 mA
Exposure Time Range0.02 – 2.0 sec
Battery2500 mAh × 4 (Li-ion)
Line Voltage100V – 240V, 50/60Hz
Country of OriginIndia
NanoPix 1 Intraoral Sensor
SpecificationDetails
Detector TechnologyAPS CMOS
ScintillatorCsI (Cesium Iodide)
Pixel Matrix1000 × 1500
Theoretical Resolution25 lp/mm
True Resolution20 lp/mm
Active Area20 × 30 mm
Mechanical Size25.4 × 36.8 × 4.4 mm
A/D Conversion16-bit
Data InterfaceUSB 2.0
Protection RatingIP68 (water & dust resistant)

Directions for Use – Orikam Hyperlight Portable X-Ray Machine

  1. Setup

    • Ensure the device is fully charged before use.

    • Place the unit on a stable surface or hold it securely for handheld use.

    • Confirm that all safety accessories (e.g., lead apron, thyroid collar) are available.

  2. Positioning

    • Align the X-ray cone with the target area of the patient’s mouth.

    • Maintain the recommended distance and angulation for accurate imaging.

    • Use a sensor holder or positioning device for consistency and precision.

  3. Image Acquisition

    • Power on the unit.

    • Select the exposure settings based on the area being imaged (refer to user manual for presets).

    • Ensure all bystanders are at a safe distance or shielded.

    • Press the exposure button to take the X-ray.

    • The unit will beep or flash when the exposure is complete.

  4. Image Transfer

    • Images are captured via an intraoral sensor (like the Nanopix RVG) connected to your computer.

    • Use wireless or USB methods (if applicable) to transfer images to your digital imaging software or EHR system.

  5. Post-Use

    • Power off the unit and place it on the charger if needed.

    • Wipe down the device with a disinfectant-compatible wipe.

    • Store in a clean, dry environment.

  6. Safety Guidelines

    • Always wear protective gear.

    • Avoid repeat exposures.

    • Follow local radiation safety regulations.

    • Regularly inspect the device for any damage.


Directions for Use – Eighteeth Nanopix Dental RVG Sensor

  1. Software & System Setup

    • Install the Nanopix imaging software on your computer using the USB or download link.

    • Follow on-screen prompts to complete the installation.

    • Install any required drivers for the sensor.

  2. Connect the Sensor

    • Plug the sensor into your computer using the provided USB cable.

    • Wait for the software to recognize the sensor.

  3. Sensor Calibration (If Required)

    • Follow the manufacturer's instructions for initial calibration to ensure optimal performance.

  4. Patient Preparation

    • Explain the procedure to the patient.

    • Place a disposable sheath over the sensor for hygiene.

    • Position the sensor inside the patient’s mouth using appropriate positioning devices.

  5. Capture the Image

    • Turn on the X-ray generator (e.g., Orikam Hyperlight).

    • The sensor automatically detects the radiation (AED Technology) and captures the image.

    • The image appears in real time on the software interface (within ~3 seconds).

  6. Image Review & Management

    • Review the captured image for clarity and positioning.

    • Use software tools to adjust contrast, brightness, or zoom if necessary.

    • Save images directly to patient records within the software.

  7. Post-Procedure

    • Remove and discard the disposable sheath.

    • Clean the sensor using a disinfectant wipe approved for electronics.

    • Properly store the sensor to avoid cable damage.


 General Safety & Maintenance Tips

  • Do not submerge the sensor or X-ray unit in liquids.

  • Handle the RVG sensor cable with care—avoid twisting or pulling.

  • Store both devices in protective cases when not in use.

  • Regularly update software and firmware for optimal performance.

  • Perform periodic checks for wear, calibration, or software errors.

  • Always wear appropriate protective gear while operating the machine.
  • Adhere to recommended safety protocols to minimize radiation exposure.
  • Regularly inspect the machine for any wear or damage before use.