Vital Blood Tubing Set Post-Pump with TP (BLU008E) is a sterile blood tubing set dialysis solution designed for blood flow during hemodialysis treatment. This blood tubing set features a post-pump configuration with an integrated Transducer Protector (TP), supporting dialysis machine protection during treatment. Made from medically biocompatible, soft and anti-kinking PVC, the hemodialysis blood tubing set is latex-free and DEHP-free. Each pack contains 30 ready-to-use sets.


Features:


  • Post-pump architecture: Optimized for secure blood transport from the machine after filtration.
  • Integrated Transducer Protector: Helps protect the dialysis machine transducer from contamination.
  • Anti-kinking tubing: Soft tubing helps support consistent blood flow during treatment.
  • Biocompatible PVC: Made using medically biocompatible material.
  • Sterile and ready-to-use: Irradiation sterilized for convenient clinical preparation.
Product CodeBLU008E
Tubing ConfigurationPost-Pump with TP
SterilizationGamma Irradiation
MaterialMedically-Biocompatible PVC
Tubing CharacteristicsSoft and Anti-kinking
LatexLatex-free
DEHPDEHP-free
Pack Size30 sets
Compatible MachinesFMC 2008/4008 series; BBraun Dialog+ System; Nikkiso DBB 03/05/06/07; Gambro AK series; Nipro Surdial series

Intended for use and operation by qualified healthcare professionals only

  1. Secure the dialyzer in the holder with the arterial end positioned downward and ports oriented appropriately for connection.
  2. Close the required clamps and position the arterial and venous drip chambers in their designated holders/sensors.
  3. Seat the blood pump segment correctly and secure the pump door.
  4. Connect the arterial and venous bloodlines to their corresponding dialyzer ports and ensure secure, finger-tight connections.
  5. Connect pressure-monitoring lines using appropriate transducer protectors and verify the required clamp positions.
  6. Prime the circuit with saline according to the applicable protocol, maintaining appropriate chamber levels and removing air from the tubing and dialyzer.
  7. Upon completion, clamp the patient ends and aseptically connect the bloodlines using the appropriate recirculation connector.