Dora Hollow Fiber Dialyzer is a low-flux hemodialysis dialyzer designed for effective removal of uremic toxins during dialysis treatment. It uses an advanced Polyethersulfone hollow fiber membrane with a 1.3m²; surface area to support efficient solute removal and ultrafiltration. Its biocompatible construction, low priming volume, and sterile presentation support patient safety and efficient clinical workflows.

Engineered for precision, the dialyzer features biocompatible construction that minimizes the risk of allergic reactions and ensures patient safety optimizing the removal of both small and middle molecular solutes during dialysis sessions.


Benefits:

  • Advanced Hollow Fiber Technology: Supports efficient solute and uremic toxin removal.
  • Polyethersulfone Membrane: Provides biocompatibility and stable ultrafiltration characteristics.
  • Low Priming Volume: Helps minimize the blood volume required to initiate dialysis.
  • Biocompatible Construction: Minimizes interaction with blood components.

Polyethersulfone (PES) hollow fiber membranes, which offer high biocompatibility and permeability. Medical-grade polycarbonate body is used in the construction of the housing, providing sterility and durability for safe use in dialysis procedures.

Model B-13PF
Membrane TypeHollow Fiber
Flux TypeLow-Flux
Membrane MaterialPolyethersulfone (PES)
Effective Surface Area1.3 m²
SterilizedYes
IndicationAcute / Chronic Renal Failure


Intended for use and operation by qualified healthcare professionals only

  1. Select as per blood volume calculation: Use the dialyzer specific for the intended hemodialysis treatment.
  2. Connect the circuits:
    - Secure the low-flux dialyzer vertically inside the holder.
    - Position the arterial (red) end down and venous (blue) end up during the initial line setup
    - Align arterial bloodline & thread into the roller-blood pump
    - Remove the protective caps and screw the male luer-lock terminal of the arterial line onto the bottom (red) inlet port of the dialyzer
    - Align venous bloodline & thread into the roller-blood pump
    - Connect the luer-lock end of the venous line onto the top (blue) outlet port of the dialyzer
  3. Observe crucial parameters: Follow applicable clinical protocols and manufacturer instructions throughout treatment.
    - Attach the arterial and venous transducer protector lines to the machine's internal pressure ports to measure post-pump arterial and venous pressures.


  • Compatibility with the Dora Hemodialysis Model series must be confirmed before use.
  • Aseptic techniques should be followed during setup to avoid contamination.
  • Patient vitals should be monitored closely throughout the dialysis process.
  • Refrigerate out of direct sunlight.
  • One use only; reuse or re-sterilization is not advised.