  • High definition 3.2” Color TFT display with user friendly interface
  • In-built Flow rate, Time/volume,Dosage/Weight Infusion modes
  • Double CPU ensures safety and reliability of infusion
  • Dual bolus: Automatic and Manual along with Anti-Bolusfunction.
  • 2000 history records and last configuration memory
  • Precise control of the infusion rate and volume with Particular stage infusion mode
  • Calibrated for all standard I V Infusion sets.
  • 3 level occlusion sensitivities setting (programmable) with picture representation
  • Audio and visual alarms for alerts
  • Vertical 5‘ Horizontal rotatable fixation clamp
Product Type : simple
BPL Syringe & Volumeteric Pump - Acura V1
BPL Syringe & Volumeteric Pump - Acura V1
Specifications:
Display 3.2 inch Color TFT (240x320 Pixels)
IV Sets Standard IV sets of 20d/ml and 60d/ml, with diameter 3.4-4.5 mm
Infusion Modes Rate Mode, Time Mode, Drug/ Weight Mode, Drip Rate Mode(optional)
Infusion Accuracy 5 5% (after calibration)
Volume Limit 1-9999 ml
Flow Rate Range 0.1 ml/hr-1200ml/hr (20d/ml IV set) 0.1 ml/hr-150ml/hr (60d/ml IV set)
Bolus Default 600ml/h, Values adjustable within 10-1200ml/hr (20d/ml IV set), Default 150ml/h ,Values adjustable within 10-150ml/hr (60d/ml IV set)
Bolus Accuracy 5 15% (after calibration)
Purge Rate 600ml/hr (20d/ml IV set), 150ml/hr (60d/ml IV set)
KVO 0.1-10ml/hr (after infusion)
Occlusion Level 3 -level sensitivities setting
Bubble Detection Ultrasonic with 3-level sensitivities setting, working frequency: 2MH215% Effective bubble detection volume - 20.025ml
Audio 8L Visual Alarm Door open, AIR in Line, Occlusion, No operation, Power OFF, Low Battery, Battery Err, Battery Lost, AC Lost, Sensor Err, Motor Err, Circuit Err.,COM. Err, Overflowing etc.
Power Supply 100V-240V AC, 50HZ/60HZ
Battery Type Internal rechargeable Ni-MH DC12V 2000mAh
Battery Backup 4 hours at 25ml/hr after fully recharged
Classification Class I, CF, IPX2
Dimensions 167mm(L) X 125mm(B) X 115mm(H) ( handgrip and clamp excluded)
Weight 1.8Kg Approx.
Operational Conditions
Temperature+5°C - +40°C
Relative Humidity ?80%
Atmospheric Pressure 70KPa - 106Kpa
Storage 8 Transportation Conditions
Temperature -22°C - +55°C
Relative Humidity 10% - 90%
Atmospheric Pressure 70KPa - 106Kpa