Niscomed ETCO2 Module - Main Stream (ET-01)

Your Advantages

Brand Niscomed

The Niscomed ETCO2 Module - Main Stream (ET-01) is a non-invasive monitoring device engineered for real-time measurement of end-tidal carbon dioxide (ETCO2) levels. This module provides precise and continuous monitoring of a patient's respiratory status, making it essential for critical care, anesthesia, and emergency medicine. It seamlessly integrates with multi-parameter patient monitors, delivering accurate and reliable ETCO2 readings directly from the patient's airway without the need for sampling lines or gas extraction.

Utilizing Mainstream Capnography Technology, the ET-01 module directly measures CO2 levels from the airway, ensuring rapid and accurate real-time readings. This technology offers instant feedback on the patient’s ventilatory status, which is crucial for detecting respiratory compromise in real time. The module supports precise ventilation management in both intubated and non-intubated patients.

This ETCO2 module is indicated for use in various clinical environments, including critical care, intensive care, anesthesia, medical/surgical units, LTAC units, emergency departments, and sleep labs. It is also suitable for use during intra-hospital and inter-hospital transport. The module is beneficial for monitoring patients requiring ventilator support, those undergoing procedural sedation, or individuals experiencing respiratory distress, respiratory arrest, asthma, or COPD.

Key Features : 

Real-time measurement of end-tidal carbon dioxide (ETCO2) levels and respiratory rate.
Utilizes Mainstream Capnography Technology for direct airway CO2 measurement.
Seamless integration with multi-parameter patient monitors for displaying ETCO2 values and waveforms.
Provides atmospheric pressure automatic compensation and operator-selectable compensation for O2, N2O, HE, and anesthetic gas.

Core Clinical FunctionMeasures end-tidal carbon dioxide (ETCO2) levels and respiratory rate.
Mode of SamplingMain stream.
Principle of OperationNon-dispersive infrared, dual wavelength.
CO2 Range0-20% by volume, 0-152 mmHg.
CO2 Accuracy0-40 mmHg ±2 mmHg; 41-70 mmHg ±5% of reading; 71-100 mmHg ±8% of reading; 101-114 mmHg ±10% of reading.
Respiration Rate Range2 to 150 breaths per minute.
Response TimeLess than 60 ms.
Serial Communication FormatRS-232, bi-directional, 19200 baud, standard N-8-1.
Atmospheric Pressure Compensation Range400 mmHg to 850 mmHg.
Gas CompensationOperator selectable for O2, N2O, HE, and anesthetic gas.