no scripts enabled
Medikabazaar
Cart
Venticare Transducer Kit - for Edwards
Venticare Transducer Kit - for Edwards: Image 1
Venticare Transducer Kit - for Edwards: Image 2
Venticare Transducer Kit - for Edwards: Image 3

Something off with this product?

Incorrect prices? Missing information? Delivery time too high?

Venticare Transducer Kit - for Edwards

View Product Details

₹667.80

₹867

23% Off

Inclusive of 5% GST

Application

Your Advantages

Brand: Venticare

Country of Origin: India

What's in the Box

2 x TruWave PX600F DPTs with two flush devices, 1 x bifurcated IV set PX2X2(macrodrip), 2 x Sets of 48” and 12” pressure tubing, 4 x 3-way stopcocks

Features:


  • Disposable pressure transducer consisting of two transducers, infusion set, pressure monitoring line, stop cock.
  • Consistent and accurate reading during monitoring
  • Better visualization of fluid
  • Easy to use with variety of interface cables can be connected to most type of monitors
  • Fully integrated flow through component design simplifies filling and debubbling
  • ETO sterilization
  • Compatibility with Edwards Systems:
    The Venticare Transducer Kit is meticulously crafted to seamlessly
    integrate with Edwards monitoring systems. This compatibility ensures a
    reliable and efficient connection, allowing for the accurate
    transmission of hemodynamic data.
  • Gold Standard Edwards Pressure Monitoring:
    Built on the legacy of Edwards pressure monitoring technology, this kit
    adheres to the gold standard in the industry. It provides a reliable and
    accurate measurement of physiological parameters, offering clinicians
    unparalleled insights into a patient's hemodynamic status.
  • Low Drift Technology for Precise Readings:
    Incorporating cutting-edge low-drift technology, the transducer kit
    minimizes signal fluctuations and ensures consistent and precise
    readings over extended monitoring periods. This technological
    advancement enhances the reliability of hemodynamic data for clinical
    decision-making.
  • Overpressure Protection for Patient Safety:
    Prioritizing patient safety, the transducer kit features overpressure
    protection mechanisms. This safeguards against pressure spikes,
    mitigating the risk of patient discomfort or injury during monitoring
    and reinforcing the commitment to the highest standards of care.
  • Integrated Flush Device for Catheter Patency:
    The integrated flush device in the transducer kit plays a crucial role
    in maintaining catheter patency. By facilitating the regular flushing of
    the catheter, it ensures the integrity of pressure monitoring,
    preventing blockages and preserving the accuracy of hemodynamic
    measurements.
Operating Pressure Range-50 to +300 mm Hg
Operating Temperature Range15 ̊ to 40 ̊C
Storage Temperature Range-25 ̊ to +70 ̊C
Sensitivity5.0μ V/V/mm Hg ± 1%
Nonlinearity and Hysteresis± 1.5% of reading or ± 1mm Hg, whichever is greater
Excitation Impedance350 ohms ± 10% with Edwards Monitor Cable attached
Signal Impedance300 ± 5%
Zero Offset± 25 mm Hg
Zero Thermal Drift± 0.3 mm Hg/ ̊C
Output Drift±1 mm Hg per 8 hours after 20 second warm-up
Sensitivity Thermal Drift± 0.1%/ ̊C
Natural Frequency40 Hz nominal for a standard kit (48”/12”);> 200 Hz for transducer alone
Leakage Current<2μ amps at 120V RMS 60 Hz
Overpressure Tolerance-500 to +5000 mm Hg
Flow rate across flush device with IV bag pressurized to 300 mm HgBlue Snap-Tab : 3±1 ml/hr Yellow Snap-Tab : 30±10 ml/hr