  • Silverline Automatic External Defibrillator is a portable electronic device that automatically diagnoses the life-threatening cardiac arrhythmias of ventricular fibrillation (VF) and pulseless ventricular tachycardia.
Specifications:
Product Code DF 401
Input 150-270 VAC , 50Hz
Battery 12V, 4.5 Ah, Rechargeable Battery Capacity 3 Hour For Monitor & 70-100 Shocks On Single Charge
Display 7 inch Colour TFT With ECG Display And Printer, Recorder
Input 150-276 VAC, 50 Hz
Output 17V At 4A
Power Consumption 30 Watts (Max) In ECG mode
Operating Temperature -5°C To +50°C
Humidity Up To 95% Non Condensing
LED Indicator Low Battery And Battery Charging
Additional General Features:
Operating Mode Manual & AED
Paper Type Printer Thermal Paper
ECG:
Lead Selection For ECG Lead I, II And III
Sweep Speed For ECG 12.5, 25, 50 mm/s
Waveform 1 ECG
Waveform 2 4 sec Delayed (Cascaded)
Freeze Mode To Freeze Up To 4 Second ECG
Frequency Response 0.5Hz To 35Hz
Patient Isolation Optical Isolation
Gain Setting 0.5, 1 And 2
CMRR = 90 dB
Digital Filter Digital Signal Processing For Good Quality Of ECG
Dimension 280x330x200 mm
Weight 6.5 Kg
Printer:
Paper Type Thermal Paper 50/55 mm Width, 20 Meters Length For 2 inch Printer
Event Printing Prints 5 Seconds Pre & Post ECG With Date, Time, Energy And Mode, Shock Status
ECG In Defib Mode Prints Last 10 sec ECG Through Paddle
Print Annotates In Difib Mode Time, Date, Mode, Lead Name, Gain, Sweep Speed
ECG In Monitor Mode Prints Last 10 sec ECG Through Paddle
Print Annotates In Monitor Mode Time, Date, Selected Lead Name, Gain, Sweep Speed
Manual Defib Check Mode Print The Status Of Shock, Energy, Date And Time
AED Mode:
Waveform Bi Phasic
AEC Shock Series Energy Level From 150 To 200J
Shock Command Front Panel Button, Shock
Charging Time Less Than 7 sec
Controls Analyze, Pause
Defibrillation Electrode Malfunction, Self Adhesive, Adult electrodes
Voice And Text Prompts Voice And Text Prompts To Guide User
Pacemaker (Optional):
Waveform Monophasic
Modes Demand Or Non Demand
Amplitude From 10 mA To 150 mA (Resolution Of 10 mA)
Pulse Width 40 ms (± 1 ms)
Frequency From 20 ppm To 250 ppm (Increments Of 1 ppm)
Refectory Period 340 ms (From 30 To 80 ppm), 240 ms (From 90 To 180 ppm)
Maximum Output Voltage 150 V
Impedance Range 200? To 1k?
SpO2 (Optional):
Range 0-100%
Accuracy 70-100% ±2%, 50-69% ±3%
Pulse Rate Displayed When PR Is Deselected
Pulse Beep Step Less Volume Control
PR Range 10-250 bpm
NIBP (Optional):
Method Oscillometric
NIBP Interval User Selectable - 3 min To 120 min
Modes Manual, Auto
Cuff Deflation Automatic
Safety Features Automatic Deflation If Cuff Pressure Exceeds 280 mmHg
Range 10-250 mmHg
NIBP Status “Ready” - When Not Taking Reading, “Measuring” - When Taking Reading, “Error” - If Reading Could Not Be Taken Due To Some Error While Measuring
Patient Type Adult, Paediatric, Neonate
Silverline Automatic External Defibrillator/ Semi Automatic Defibrillator - DF 401
Silverline Automatic External Defibrillator/ Semi Automatic Defibrillator - DF 401
  • Rechargeable lithium battery with charger (11.1v)
  • 20 meters length for 2 inch printer
  • Charge command automatic after identifying arrhythmia
  • Pitch variation with change in oxygen saturation
  • Charging time less than 6 seconds
  • Operation-by front panal key board, encoder & on-off by front panel push button
  • Optional:
  • SpO, NIBP, Pacemaker, EtCO