Volk SOLR Surgical System 200 (VSOLR)
Volk SOLR Surgical System 200 (VSOLR): Image 1
Volk SOLR Surgical System 200 (VSOLR): Image 2
Volk SOLR Surgical System 200 (VSOLR): Image 3
Volk SOLR Surgical System 200 (VSOLR): Image 4

Your Advantages

FREE DELIVERY

7 DAY REPLACEMENT

HASSLE FREE

SHELF LIFE GUARANTEE

100% AUTHENTIC

FREE SHIPPING

Brand Volk

The Volk SOLR Surgical System 200 (VSOLR) is an advanced non-contact indirect ophthalmic surgical system engineered for enhanced intraoperative retinal visualization. It supports complex posterior segment surgeries, including vitreoretinal procedures, by providing clear, wide-field views of the retina. This system is intended for use in the diagnosis and therapy of intraocular abnormalities when attached to a surgical microscope.

Integrating Volk's proprietary wide-field optics, the SOLR Surgical System 200 features an expanded condensing lens that ensures an unobstructed optical and illumination path, delivering shadow-free, crystal-clear views for both the surgeon and assistant. The system includes a 200 mm Condensing Lens, a Lens Arm, a Rotation Base, and surgical lenses (MidField & WideAngle), along with a ROLS Infinity Reinverter.

Components of the Volk SOLR Surgical System 200 are designed for steam sterilization, with optical components such as the condensing and surgical lenses compatible with pre-vacuum steam sterilization cycles at a minimum temperature of 132°C for 3 minutes. The Volk SOLR Surgical System is classified as a US FDA Class 1 medical device and is 510(k) Exempt under FDA regulation 21 CFR 878.4700.

Key Features : 

Supports complex posterior segment surgeries and vitreoretinal procedures for enhanced retinal visualization.
Features an expanded condensing lens for shadow-free, crystal-clear views for both surgeon and assistant.
Components are compatible with steam sterilization, including pre-vacuum cycles at 132°C for 3 minutes for optical lenses.
Classified as a US FDA Class 1 medical device, 510(k) Exempt under FDA regulation 21 CFR 878.4700.

MaterialOptical components
Procedure / ApplicationRetinal visualization, vitreoretinal surgery, posterior segment procedures
SterilitySterilizable components
Sterilization CompatibilitySteam sterilization (pre-vacuum cycle, 132°C minimum, 3 minutes for lenses)
Regulatory ApprovalUS FDA Class 1, 510(k) Exempt (21 CFR 878.4700)