no scripts enabled
Medikabazaar
Cart
(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT - 160 Slice
(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT - 160 Slice: Image 1
(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT - 160 Slice: Image 2
(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT - 160 Slice: Image 3

Your Advantages

FREE DELIVERY

7 DAY REPLACEMENT

HASSLE FREE

SHELF LIFE GUARANTEE

100% AUTHENTIC

FREE SHIPPING

(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT - 160 Slice

₹2,60,00,000

₹2,80,00,000

7% Off

Exclusive of 5% GST

Type

Pack Size

Variant unavailable, Please select another variant

Pre Owned Toshiba / Canon Aquilion Prime 160 slice Cardiac CT

  • Patient accessibility improvement by 78 cm bore Gantry Aperture Size

  • Tube: 7.5 MHU, 10-600mA range

  • Generator: 72kW

  • Rotation Time: 0.35 sec

  • Gantry Physical: ±30°

  • Detector:

  • Rows: 80

  • Slice Thickness: 0.50 mm

  • Width: 40mm

  • Low Contrast Resolution of 2mm @ 0.3% = Industry Best Resolution

  • i-station Interface

  • Ultra Fast Reconstruction

  • 2,572 views/sec high clinical detailed data.


  • Table:
  • Height Adjustable

  • 47 cm couch width – widest in industry

  • 205 kg table limit with full accuracy

  • Table lowest height of 33 cm - for the pediatric, the elderly, and the physically challenged

  • 1800 mm scan range - All regions attainable in a single set-up, essential for Trauma, Multiple regions, ICU etc.

    Spatial Resolution:
  • 21.5 lp/cm at MTF 0%
  • 14.5 lp/cm at MTF 2%
  • 8.0 lp/cm at MTF 50%

*For reference


SMOOTH & EFFICIENT WORKFLOW:

Migrating the Basic Technology Developed for Aquilion ONE 640 slice CT scanner
Active Collimator (up to 20% dose reduction)


  • The active collimator eliminates X-rays that are not used for image reconstruction in helical scanning.
  • The collimator operates automatically at the start and end of scan range limiting the extend of X-ray beam, permitting further dose reduction.
  • With active collimation the exposure can be reduced by up to 20%.

AIDR (Adaptive Iterative Dose Reduction) (up to 75% dose reduction, HQ Image)

  • AIDR is an image reconstruction algorithm that allows high image quality to be achieved at a low exposure dose.

  • Noise components are selectively extracted from signal in an iterative process improving image quality.

  • With AIDR the exposure can be reduced by up to 75% maintaining superb image quality.

TOSHIBA’s Unique SEMAR

Single Energy Metal Artifact Reduction

Ideal for Imaging of:

  • Cardiac CT scanning

  • Brain Perfusion scans

  • Long Length Angios

  • Chest scans in less than 10 seconds, less breath hold

  • Fast Trauma scans

  • Excellent 3D images

Country of Origin: Japan

US-FDA Approval: Yes