Something off with this product?
Incorrect prices? Missing information? Delivery time too high?
5/5
(23)
Contec Syringe Pump (SP950)
View Product Details
₹17,062.50
₹26,250
35% Off
Inclusive of 5% GST
Model
Buy 11 & Get 1% OFF
Unit price : ₹16,891.88
Buy 21 & Get 3% OFF
Unit price : ₹16,550.63
Buy 31 & Get 4% OFF
Unit price : ₹16,380
Your Advantages
Delivery By
Enter location
Subtotal :
₹17,062.50
Want to buy bulk quantity?
Brand: Contec
Country of Origin: China
What's in the Box
1 x Syinge Pump, 1 x Mounting Bracket, 1 x Power Cord, 1 x User Manual, 2 x Fuses
Contec Syringe Pump SP950 is a single-channel syringe infusion pump for precise and controlled intravenous (IV) delivery of fluids in ICUs, wards, operating theatres and patient transport. It takes 10, 20, 30 and 50 ml syringes, recognises the loaded syringe size automatically, and delivers with ±3% accuracy. The clinician has to the infusion rate and total volume. After infusion in completed, the pump switches to KVO (keep vein open) mode at an adjustable 0.1–5 ml/h.
It's purge (quick-feed) function gives rapid delivery when needed. The occlusion alarm threshold has three levels (low, middle, high), so it can be matched to the line and the patient.
Audible and visual alarms cover occlusion, syringe fall-off, near-empty and empty syringe, low battery, motor or pressure failure, and no-operation at power-on.
With a 2.8" TFT LCD display real-time values such as accumulated volume and remaining time are easier to read even from a distance. Settings are preserved after shutdown so no need to reconfigure after power failure, and system and syringe-type settings are password protected.
The built-in 7.4 V lithium battery [capacity: 3500 mAh] switches over automatically from AC and runs for at least 2 hours at 5 ml/h or 500 ml/h on a full charge.
Key Features:
- Precise infusion: ±3% accuracy supports controlled medication delivery.
- Flexible operation: Rate, Time, and Gradient modes accommodate varied infusion protocols.
- Enhanced safety: Air bubble and adjustable occlusion detection help monitor infusion conditions.
- Continuous backup: Rechargeable lithium battery supports operation during transport or power interruptions.
- Convenient medication management: Drug library enables pre-setting of commonly used medications.
- Clinical reliability: CE and ISO13485 certifications support compliance with international medical standards.
Who it is for : Hospitals, nursing homes, ICUs and NICUs, emergency and ambulance services that need an affordable, accurate syringe pump for continuous low-volume infusions.
Not sure whether you need a syringe pump or a volumetric infusion pump? Click to read more on Infusion Pump or Syringe Pump ? or our hands-on Contec SP950 Review
Manufacturer: Contec Medical Systems Co., Ltd., Qinhuangdao, China
| Brand | Contec |
| Model | SP950 |
| Display | 2.8" TFT LCD |
| Type | Single-channel syringe infusion pump |
| Syringe Sizes | 10ml, 20ml, 30ml, 50/60ml |
| Syringe Recognition | Automatic size detection with mismatch alarm |
| Infusion Rate | 10 ml 0.1-100, 20 ml 0.1-200, 30 ml 0.1-300, 50 ml 0.1-500 ml/h |
| Increment | 0.1 ml/h |
| Purge (Quick Feed) | 100 / 200 / 300 / 500 ml/h |
| Injection Speed Range | 0.1-100 / 200 / 300 / 500 ml/h |
| Accuracy | ±3% |
| Volume | 0.1~9999 ml |
| KVO Rate | 0.1-5 ml/h, adjustable |
| Occlusion levels | High - 100 ± 35 kPa |
| Medium - 70 ± 30 kPa | |
| Low - 40 ± 16 kPa | |
| Alarms | Occlusion, syringe fall-off, near empty, empty, low battery, motor failure, pressure failure, communication fault, no operation |
| Water Resistance | IPX2 |
| Infusion Mode | Rate, Time, Gradient, KVO Mode, Bolus |
| Air Bubble Detection | Supported |
| Drug Library | Supported |
| Battery Backup | 2 hours operation at 5ml/h or 500ml/h after Full Charge |
| Power consumption | 20-30 VA |
| Safety classification | Class II, internally powered, type BF |
| Battery Power | Rechargeable Li-ion battery 7.4v/3500mAh |
| Power Supply | AC 100-240 V~, 50/60 Hz |
| Operating Conditions | 5-40 °C, 20-90% RH, 860-1060 hPa |
| Storage Conditions | −20 to +55 °C, ≤90% RH, non-condensing |
| Dimensions | 310 × 140 × 135 mm |
| Weight | 1.7 Kg |
| Certifications | CE, ISO13485 Approved |
Intended for use and operation by qualified healthcare professionals only
- Select the appropriate syringe as per compatible sizes
- Position it securely in the syringe holding bracket.
- Select the prescribed infusion mode: Rate, Time, or Gradient as per patient requirement.
- Set the prescribed infusion parameters according to the calculated infusion rate.
- Select appropriate occlusion detection pressure: Low, Middle, or High.
- Verify the syringe and infusion settings before starting the dosage delivery.
- Periodically monitor the pump alerts and infusion status throughout operation.
- Follow applicable protocols and manufacturer instructions for storage & handling.
The SP950 supports variable infusion rates depending on syringe size: 0.1–200 ml/h for 10 ml syringes, 0.1–400 ml/h for 20 ml syringes, 0.1–600 ml/h for 30 ml syringes, and 0.1–1200 ml/h for 50 ml syringes in 0.1 ml/h steps. Bolus rates are proportionally higher, enabling rapid medication delivery when clinically required. Accuracy is maintained at ±3% across all settings.
The pump includes multiple safety alarms: occlusion detection, syringe fall-off, low battery, motor failure, communication abnormalities, pressure failure, and near-empty/empty syringe alerts. Alarm brightness, volume, and pressure range thresholds (low, middle, high) are user-adjustable to suit different clinical environments. The pump also signals inactivity when powered on without operation.
KVO (Keep Vein Open) mode automatically activates after infusion completion to maintain catheter patency and prevent blockage. The KVO rate is adjustable from 0.1–5 ml/h, allowing clinicians to tailor the maintenance flow to patient needs and clinical protocols.
The SP950 features a rechargeable 7.4 V lithium battery (3500 mAh). It switches over automatically when AC power is lost, charges automatically, and runs the pump for at least 2 hours at 5 ml/h or 500 ml/h on a full charge.
The Contec SP950 supports 10, 20, 30, and 50 ml disposable syringes. The pump detects the syringe size and triggers an alarm if it does not match the selected setting. Accuracy is maintained by selecting the correct syringe type in the settings.
The SP950 is classified as Class II medical equipment, internally powered, Type BF. System parameters and syringe type settings are password-protected to prevent unauthorized changes, supporting consistent and safe operation across clinical settings.
Occlusion is a blockage in the line that stops the drug from reaching the patient, causing pressure to build up. Contec SP950 measures line pressure and triggers an alarm when it exceeds the selected threshold: low (40 ± 16 kPa), middle (70 ± 30 kPa), high (100 ± 35 kPa)
Purge (quick feed) pushes fluid quickly to prime the line or deliver a short, rapid volume of fluid. On the Contec SP950, the quick-feed rate depends on syringe size: 100, 200, 300, and 500 ml/h for 10, 20, 30, and 50 ml syringes, respectively.
Load and clamp the prefilled syringe in the holder, then confirm the detected syringe size. Set the infusion rate and total volume, select the occlusion level, and prime the line according to the device instructions. Connect to the patient and press start. Monitor the infusion and alarms throughout delivery. Once the set volume is delivered, the pump switches to Keep Vein Open (KVO) mode.
A syringe pump like the Contec SP950 is suitable for delivering small, precise fluid volumes at low infusion rates. Typical applications may include sedation, inotropes, insulin, and neonatal infusions, depending on the prescribed therapy and device compatibility. A volumetric infusion pump is generally suitable for delivering larger fluid volumes from IV bags. Select the pump based on clinical requirements, prescribed settings, and manufacturer instructions.
Product Insights
Guides and articles about Syringe Pump.