Siemens Mammomat 3000 Nova
MBS001
MAMMOMAT 3000 Nova
Because she deserves the very best
Siemens Nova 3000
MAMMOMAT 3000 Nova offers the most versatile technology for breast imaging. Its open
design, integrated features, and work-horse reliability ensure the highest performance.
MAMMOMAT 3000 Nova maximizes system utilization potential, return on investment and
space savings. Imagine the efficiency of using one system for:
Screening
Siemens™ engineers added new design elements, softer lines and a fresh look for MAMMOMAT 3000
Nova, while preserving the highly-appreciated features and options of our proven M3000.
Superior Accessibility
The slim tube-head design and narrow base allows easy, proper positioning of patients, including those
in wheelchairs. Excellent ergonomic conditions are pre-served for both operator and patient.
Generous gantry free-space
The 65-cm gantry opening (SID) allows easy patient positioning.
Opdose: Optimized dose Mo/Mo, Mo/Rh, W/Rh
Siemens invented the dual-track X-ray tube, with Molybdenum and Tungsten anode materials in 1994,
and it has gained popularity with every installation. The Opdose® system auto- selects the best
anode/filter combination (Mo/Mo, Mo/Rh, W/Rh), and the lowest dose, according to individual breast
characteristics. This is particularly important for younger women whose breasts normally have higher
density and often require higher dose. By selecting W/Rh in appropriate cases, Opdose can save up to
60% dose over a comparable Mo/Mo exposure.
Generator
High-voltage wave form: Multipulse
Exposure voltage: 23kV to 35kV, adjustable in increments of 1kV
Exposure times: From 10 ms to 4s
X-ray tube assembly
X-ray tube (Mo resp. Mo/W): Molybdenum/Tungsten rotating anode tube with Beryllium window, P40
Mo/W four focus tube with nominal focal spot value 0.1/0.3 (star pattern), 0.15/0.3 (DIN/IEC 336/1993)
Tube current (Mo resp. Mo/W): Molybdenum max. large focal spot: 150 mA at 25 kV,
max. small focal spot: 28 mA at 25 kV.,
Tungsten max. large focal spot. 188 mA at 25 kV,
max. small focal spot 34 mA at 25 kV.
Total heat storage capacity: 1 100 00 Joule (1 500 00 HU)(IEC 613/1989)
Anode heat storage capacity: 120 000 Joule (162 000 HU)(IEC 613/1989)
Anode speed: 8,800 r.p.m.
Filter: Mo tube : 30μm Molybdenum, 25μm Rhodium
Mo/W tube: 30μm Molybdenum, 25μm Rhodium, 50μm Rhodium
X-ray stand
Height adjustment: Motorized, 650 mm to 1350 mm floor to object table (in all angles)
Swivel range: +135° / -180°
Rotation of swivel arm: Motorized, isocentric
Source to Image Distance (SID): 65 cm
Grid: Reciprocating; Pb 4/27 (4:1 ratio, 27 lines/cm)
Compression device: Opcomp, motorized compression initiated via footswitch or manual adjustment