no scripts enabled
Medikabazaar
RefurbishedCT ScanSiemens Biograph PET CT mCT - 64 Slice
Siemens Biograph PET CT mCT - 64 Slice
CT Scan

Siemens Biograph PET CT mCT - 64 Slice

MBS001

starts from4,20,00,000Exclusive of 5% GST
Product Description

STRATON X-ray tubeprovides fast 0.33 s CT rotation speed and high resolution.

LSO crystals and HI-REZ detectorsoffer industry-leading PET performance.

TrueVextends the PET field of view (FOV) by 33% and increases NEMA count rate by >70%.

HD·PEToffers uniformity, high-resolution, and 2x better contrast over conventional PET.

z-Sharpprovides .33 mm resolution at any scan and rotation speed and at any position.

STRATON X-ray tube

Our unparalleled 0 MHU STRATON X-ray tube has caused a paradigm shift in CT imaging. The tube’s direct anode cooling eliminates the need for heat storage, permitting a compact design and the fastest CT gantry rotation for all applications. In cardiac imaging, where the ability to freeze motion is critical, Biograph™ 40 and 64 provide you with super-fast rotation time, making noninvasive cardiac diagnosis routinely available.

To increase temporal resolution, the proprietary STRATON X-ray tube enables a fast gantry rotation time of 0.33 s, resulting in motionand artifact-free imaging of the heart.

z-Sharp technology

Instead of decreasing the size of detector elements to improve spatial resolution, z-Sharp technology on the Biograph 40 and 64 utilizes two overlapping X-ray beams, resulting in significantly increased resolution without a corresponding increase in dose. This provides you with the industry-leading isotropic resolution of 0.33 mm at any scan and rotation speed, and at any position within the scan field. In addition, with our proprietary z-UHR technology, the system adapts for ultra-high resolution bone imaging for wrist, joint, or inner ear studies. We push the boundaries of spatial resolution even further providing unparalleled 0.24 mm isotropic resolution — until now seen only with research flat panel and Micro CT technology.

Conventional PET or HD•PET:

What’s the real difference?

When a photon strikes a crystal, it travels a certain distance before its energy is converted into light. If the photon comes from the center of the field of view (FOV),the line of response (LOR) is likely to be correctly localized in the crystal in which the photon entered. The further away from the center of the FOV, the less likely the LOR will be calculated correctly because the photon will hit the crystal on an angle and continue traveling to another crystal before it lights up. A Point Spread Function (PSF) describes the response of an imaging system to a point source or point object. A system that knows the response of a point source from everywhere in its FOV can use this information to recover the original shape and form of imaged objects. PSFs are used in precision imaging instruments, such as microscopy, ophthalmology, and astronomy (e.g. the Hubble telescope) to make geometric corrections to the final image.

Conventional PET uses the same reconstruction principles across the entire FOV and does not take into account the detector geometry and mispositioning of the LORs. This results in fuzzy edges and increased distortion further

from the center of the FOV.

LSO: state-of-the-art crystal technology

With more than 10 years of experience in Lutetium Oxyorthosilicate (LSO) scintillator crystal technology, Siemens is a pioneer in innovative PET imaging techniques. The Biograph TruePoint PET·CT employs patented LSO PET detectors that provide clear and fast images. A PET scanner’s performance greatly depends on the scintillation properties of the detector crystal material. With a fast scintillation decay time of 40 ns and the highest density available, LSO crystals offer the best combination of properties of any PET scintillator known today. LSO offers a fast coincidence timing window of 4.5 ns for efficient rejection of random events and enough light output for high energy resolution discrimination to facilitate the efficient rejection of randoms — all to provide high count rate statistics, which are essential to high speed PET scanning.

Full Product Description

The Siemens Biograph mCT brings reproducible quantification to molecular imaging. Detect, characterize and monitor the tiniest cancer lesions with reproducible quantification, thus supporting more cost-effective treatment. Quantify absolute myocardial blood flow, to make more accurate treatment decisions and minimize risk to your patients. making more accurate treatment decisions, minimizing risk to your patients. Quantify1 amyloid deposits in the brain, to support dementia diagnosis.

Excellence in cardiac imaging Biograph mCT provides excellence in cardiac imaging through innovative PET and CT technologies. The patented Prompts Gamma Correction provides clarity in PET cardiac imaging with a reduction in noise while the highly-renowned and compact STRATON™ X-ray tube with z-Sharp™ delivers true temporal resolution of up to 150 ms for motion-artifact-free CT imaging of the heart.

Siemens Biograph mCT PET CT Features:

Features of the Siemens Biograph mCT• Whole-body PET-CT scans in only 5 minutes• Unprecedented throughput for true shared service capability in CT and PET• Outstanding image quality• More comfortable examinations• Scalable, reliable and upgradeable• Low patient doses• STRATON X-ray tube enables 0.30 second gantry rotations• x-Sharp provides the highest spatial resolution available• CARE Dose4D offers real-time dose modulation• Adaptive Dose Shield eliminates clinically irrelevant dose for pre and post spiral scans• Adaptive ECG-Pulsing and Adaptive Cardio Sequence compensate for arrhythmia• Adaptive 4D Spiral with continuously repeated bi-directional table movement overcomes the coverage limitation of a static detector design• TrueV provides the longest axial FOV• TrueC offers model-based scatter correction calculated independently for every patient and bed position• Large bore, short tunnel and a very compact footprint• LSO crystals facilitate faster scans• HI-REZ offers exceptional resolution Siemens Biograph mCT Tech Specs (Technical Specifications)• Slices: 40, 64, and 128• Bore: 78 cm• Maximum patient weight: 227 kg (500 lb)• Isotropic CT resolution with z-UHR: 0.24 mm• CT rotation time: 0.30 second• Power: 100 kW with 128-slice CT• Field of View: 21.6 cm axial PET FOV with TrueV• HD-PET offers 2x improvement in signal-to-noise and uniform resolution• ultraHD-PET offers 4x improvement in signal-to-noise and uniform resolution• 5 minute PET-CT imaging with TrueV and ultraHD-PET
Technical Specifications

Submit an Enquiry

Full Name *

Hospital / Organization *

Email *

Phone *

Product / Generic Name *

Message