KellyMed Infusion Pump ZNB-XA II

In stock
SKU
MBKM0005
Features: • Model:-ZNB-XA II • Pumping mechanism:-Curvilinear peristaltic • IV Set:-Compatible with IV sets of any standard • Flow Rate:-1-1200 ml/h(in 0.1ml/h increments) • Purge,Bolus:-Purge when pump stops,bolus when pump starts,rate at 500,800,1200ml/h • Accuracy:=±3% • VTBI:-1-20000ml(in 0.1 ml increments) • Infusion Mode:-ml/h,drop/min,time-based,body weight,nutrition • KVO Rate:-1-5ml/h(in 0.1 ml/h increments) • Alarms:-Occlusion,air-in-line,door open,end program,low battery,end battery,AC power off,motor malfunction,system malfunction,reminder alarm • Additional Features:-Real-time infused volume,automatic power switching,mute key,purge,bolus,system memory,history log • Occlusion Sensitivity:-High, medium, low • History Log:- 50000 events • Air-in-line Detection:-Ultrasonic detector • Wireless Management:-Optional • Drop Sensor:-Optional • Vehicle Power(Ambulance):-12±1.2V • Power Supply,AC:-110/230V(optional),50-60 Hz,20VA • Battery:-9.6±1.6V,rechargeable • Battery Life:-5 hours at 25 ml/h • Working Temperature:-10-30°C • Relative Humidity:-30-75% • Atmospheric Pressure:-860-1060hpa • Size:-130*145*228mm • Weight:-2.5kg • Safety Classification:-Class I,type CF
KellyMed Infusion Pump ZNB-XA II_00
KellyMed Infusion Pump ZNB-XA II_00
Specification: • Model:-ZNB-XA II • Pumping mechanism:-Curvilinear peristaltic • IV Set:-Compatible with IV sets of any standard • Flow Rate:-1-1200 ml/h(in 0.1ml/h increments) • Purge,Bolus:-Purge when pump stops,bolus when pump starts,rate at 500,800,1200ml/h • Accuracy:=±3% • VTBI:-1-20000ml(in 0.1 ml increments) • Infusion Mode:-ml/h,drop/min,time-based,body weight,nutrition • KVO Rate:-1-5ml/h(in 0.1 ml/h increments) • Alarms:-Occlusion,air-in-line,door open,end program,low battery,end battery,AC power off,motor malfunction,system malfunction,reminder alarm • Additional Features:-Real-time infused volume,automatic power switching,mute key,purge,bolus,system memory,history log • Occlusion Sensitivity:-High, medium, low • History Log:- 50000 events • Air-in-line Detection:-Ultrasonic detector • Wireless Management:-Optional • Drop Sensor:-Optional • Vehicle Power(Ambulance):-12±1.2V • Power Supply,AC:-110/230V(optional),50-60 Hz,20VA • Battery:-9.6±1.6V,rechargeable • Battery Life:-5 hours at 25 ml/h • Working Temperature:-10-30°C • Relative Humidity:-30-75% • Atmospheric Pressure:-860-1060hpa • Size:-130*145*228mm • Weight:-2.5kg • Safety Classification:-Class I,type CF
Write Your Own Review
You're reviewing:KellyMed Infusion Pump ZNB-XA II
Your Rating

Related products

Check items to add to the cart or

WhatsApp chat

WhatsApp chat